Power sources that can be usedPower sourcesPower sources that can be usedAn external power source that fulfills the following criteria is necessary for charging
this vehicle. Confirm this before charging.Warning:Warnings for electrical faultsMake sure to observe the precautions in this Owner’s Manual when charging the vehicle.Failure to use a power source that fulfills the requirements, or failure to observe
regulations while charging could lead to an accident, possibly resulting in death
or serious injury.Power sourcesConnect to an AC 120 V outlet (NEMA 5-15R) with a Ground-Fault Circuit-Interrupter
(GFCI) and a circuit breaker. Use of a 15A individual circuit is strongly recommended
to ensure AC charging cable will operate properly.When charging outdoors, make sure to connect to a weatherproof outlet that is certified
for outdoor use. Checking Ground-Fault Circuit-Interrupter (GFCI) operation before
its use is recommended.Outlets that can be connectedNEMA 5-15R outletThe illustration is an example shown for demonstration purposes, and may differ from
the actual configuration.Note:The charging environmentFor safe charging, the following charging equipment and settings are recommended.Weatherproof outletWhen charging outdoors, connect the plug to a weatherproof outlet, and ensure that
the plug remains waterproof while the plug is connected.Dedicated circuitTo reduce the risk of fire, connect only to an at least 15A branch circuit with an
over-current protection in accordance with the National Electric Code, ANSI/NFPA 70.To reduce the risk of electric shock when working with the plug, connect to a outlet
with a Ground-Fault Circuit-Interrupter (GFCI) or that has an Earth Leakage Circuit
Breaker installed.When your circuit breaker trips during charging (vehicles with 7-inch multi-information
display)The upper limit of the charging current can be changed in “
Vehicle Settings” on the multi-information display.Press
or
of the meter control switches to select
.Press
or
of the meter control switches to select “
Vehicle Settings”, and then press and hold
.Press
or
of the meter control switches to select “
Charging Settings”, and then press
. The “
Charging Settings” screen will be displayed.Press
or
of the meter control switches to select “
Charging Current”, and then press
. The “
Charging Current” screen will be displayed.Press
or
of the meter control switches to select “
16A”*1 or “
8A”, and then press
. During charging, the maximum charging current will be restricted to the set current
or lower.*2If the breaker still trips while charging, even after changing the upper limit of
the charging current, check if the connected power source meets the specified charging
conditions. (Power sources)*1Vehicles with 7 kW onboard traction battery charger only*2Restricting the charging current will lengthen the charging time.When your circuit breaker trips during charging (vehicles with 12.3-inch multi-information
display)The upper limit of the charging current can be changed in “
Vehicle Settings” on the multi-information display.Press and hold
to display the cursor on the content display area (center) of the multi-information
display.Press
or
of the meter control switches to select
and then press
.Press
or
of the meter control switches and select “
Vehicle Settings”. Then press and hold
.Press
or
of the meter control switches to select “
Charging Settings”, and then press
. The “
Charging Settings” screen will be displayed.Press
or
of the meter control switches to select “
Charging Current”, and then press
. The “
Charging Current” screen will be displayed.Press
or
of the meter control switches to select “
16A”*1 or “
8A”, and then press
. During charging, the maximum charging current will be restricted to the set current
or lower.*2If the breaker still trips while charging, even after changing the upper limit of
the charging current, check if the connected power source meets the specified charging
conditions. (Power sources)*1Vehicles with 7 kW onboard traction battery charger only*2Restricting the charging current will lengthen the charging time.Warning:Charging
Power sources precautionsPower sources precautionsObserve the following precautions.If you do not follow them, fire, electrical shock or damage may occur, possibly resulting
in death or serious injury.Connect to an AC 120 V outlet (NEMA 5-15R) with a Ground-Fault Circuit-Interrupter
(GFCI) and supplied by a circuit breaker per your local code. Use of a 15A individual
circuit is strongly recommended.Do not connect the AC charging cable to a multi-outlet adaptor, multi-plugs, or conversion
plug.Connecting the AC charging cable to an extension cord is strictly prohibited. The
extension cord may overheat and does not contain a Ground-Fault Circuit-Interrupter
(GFCI).The leakage detection function of the CCID (Charging Circuit Interrupting Device)
(Electrical leakage detection function) may not operate correctly.Do not connect to a branch electrical socket.Make sure to connect the charging connector and AC charging inlet directly. Do not
connect a converting adaptor or extension cord between the charging connector and
AC charging inlet.